Prev. Page | Next Page |
1. | Remove pump from well, disconnect air volume control line, cap snifter valve, and connect to a short suction pipe into container of water as illustrated. |
A. | On all shallow well models, leave pressure pipe pluggd, prime pump to service out-let, fill container with water and start pmp. When pump is normal, the pressure will rise above 55 pounds tank pressure - see test pressure on side of tank. |
B. | On all deep well single stage pumps. plug pressure and use same method as "A" - see test pressure on side of tank. |
C. | On all stage pumps use a 200 pound pressure gauge in pressure pipe and use Method A. In this test be careful to check both pressure gauges for correct test. |
Taken from Ruth/Berry Service Manual