Prev. Page |
HP | VOLTS | Max.
Fuse Size |
Minimum Wire Size from Pump Motor to Meter - Distance in Feet | |||||||||||||||||||
50 | 100 | 150 | 200 | 250 | 300 | 350 | 400 | 450 | 500 | 550 | 600 | 650 | 700 | 750 | 800 | 850 | 900 | 950 | 1000 | |||
1/3 | 115 | 25 amp | 14 | 14 | 14 | 14 | 12 | 12 | 12 | 10 | 10 | 10 | 8 | 8 | 8 | 6 | 6 | 6 | 6 | 4 | 4 | 4 |
230 | 15 amp | 14 | 14 | 14 | 14 | 14 | 14 | 14 | 14 | 12 | 12 | 12 | 12 | 10 | 10 | 10 | 10 | 10 | 10 | 10 | 10 | |
1/2 | 115 | 30 amp | 14 | 14 | 14 | 12 | 12 | 10 | 10 | 10 | 8 | 8 | 8 | 6 | 6 | 6 | 4 | 4 | 4 | 4 | 4 | 2 |
230 | 15 amp | 14 | 14 | 14 | 14 | 14 | 14 | 12 | 12 | 12 | 10 | 10 | 10 | 8 | 8 | 8 | 8 | 8 | 8 | 6 | 6 | |
3/4 | 115 | 40 amp | 14 | 14 | 12 | 12 | 10 | 10 | 8 | 8 | 8 | 6 | 6 | 6 | 4 | 4 | 4 | 4 | 4 | 2 | 2 | 2 |
230 | 25 amp | 14 | 14 | 14 | 14 | 14 | 12 | 12 | 12 | 10 | 10 | 10 | 8 | 8 | 8 | 8 | 8 | 8 | 6 | 6 | 6 | |
1 | 115 | 50 amp | 14 | 12 | 10 | 10 | 8 | 8 | 8 | 6 | 6 | 6 | 4 | 4 | 4 | 4 | 4 | 2 | 2 | 2 | 2 | 2 |
230 | 25 amp | 14 | 14 | 14 | 14 | 12 | 12 | 12 | 10 | 10 | 10 | 8 | 8 | 8 | 8 | 8 | 8 | 6 | 6 | 6 | 6 | |
1-1/2 | 115 | 60 amp | 14 | 12 | 10 | 8 | 8 | 6 | 6 | 6 | 4 | 4 | 4 | 4 | 2 | 2 | 2 | 2 | 0 | 0 | 0 | 0 |
230 | 30 amp | 14 | 14 | 12 | 12 | 12 | 12 | 10 | 10 | 8 | 8 | 8 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 4 | |
2 | 115 | 70 amp | 14 | 12 | 10 | 8 | 6 | 6 | 6 | 4 | 4 | 4 | 2 | 2 | 2 | 2 | 0 | 0 | 0 | 0 | N/A | N/A |
230 | 35 amp | 14 | 14 | 12 | 10 | 10 | 8 | 8 | 8 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 4 | 4 | 4 |